DBC0115F1VXX-X

DBC0115F1VXX-X

DIPLEXER 555-960/1695-2690

Kaelus world proven outdoor solutions provide strong RF performance coupled with rugged features. The DBC0115 dual band combiner combines the 555-960 MHz and 1695-2690 MHz frequency bands. The DBC0115 can be used at either the BTS or antenna end of the feeder. Single and twin units are available.

FEATURES

  • Designed for multi-band, co-located sites
  • Multiple DC/AISG bypass configurations available with built-in lightning protection
  • Single and twin configurations available
  • Suitable for outdoor and indoor applications
  • UMTS & LTE ready
  • Wall or mast mounting

technical specifications
Band Name555 - 9601695 - 2690
Passband555 - 960MHz1695 - 2690MHz
Insertion loss0.1dB typical (0.2dB maximum)0.1dB typical (0.2dB maximum)
Return loss> 20dB> 20dB
Maximum input power250W (average) / 2kW (PEP)250W (average) / 2kW (PEP)
Intermodulation products< -160dBc at 2 x 43dBm TX Carrier
Rejection high band50dB minN/A
Rejection low bandN/A50dB min
dc / aisg
FeatureDC-FIXEDDC-AUTOSENSE
Passband0 - 3MHz0 - 3MHz
Insertion loss, single DC/AISG pass1dB maximum1dB maximum
Return loss, single DC/AISG pass12dB minimum12dB minimum
Insertion loss, two DC/AISG pass4.5dB maximum4.5dB maximum
Return loss, two DC/AISG pass6dB typical6dB typical
Input voltage range8 – 31V DC8 – 31V DC
DC current rating3A2A
Compliance3GPP, TS 25.4613GPP, TS 25.461
Port priority (combiner mode)N/ARefer Ordering Information
environmental
For further details of environmental compliance, please contact Kaelus.
Temperature range-40ºC to +65ºC | -40ºF to +149ºF
Ingress protectionIP67
Lightning protection5kA maximum (8/20us)
MTBF> 1,000,000 Hours
ComplianceETS 300 019 1-4 (OPERATIONAL)
ETS 300 019 1-1 (STORAGE)
mechanical
FeatureDC-FIXEDDC-AUTOSENSE
Dimensions H x D x W (single unit)108 x 142 x 55mm | 4.25 x 5.59 x 2.18in108 x 142 x 66mm | 4.25 x 5.59 x 2.60in
Dimensions H x D x W (twin unit)108 x 142 x 112mm | 4.25 x 5.59 x 4.51in108 x 142 x 134mm | 4.25 x 5.59 x 5.28in
Weight (single unit)1.5kg | 3.31lbs1.6kg | 3.53lbs
Weight (twin unit)3.1kg | 6.83lbs3.2kg | 7.06lbs
FinishPainted, NCS 1502-R
Wind LoadFront 116N, Side 32N (Single)
Front 87N, Side 96N (Twin)
At 74m/s (AS/NZS 1170-2-2011 Structural design - Wind actions - Cyclone areas)
Connectors4.3-10 (F) x 3 long neck (single unit)
4.3-10 (F) x 6 long neck (twin unit)
MountingPole/wall bracket supplied with two metal clamps for 45-178 mm diameter poles
ordering information
dc fixed
ModelDC PATHMount
DBC0115F1V10-1NO DC PATHSINGLE
DBC0115F1V10-2NO DC PATHTWIN
DBC0115F1V13-1DC ALL PATHSSINGLE
DBC0115F1V13-2DC ALL PATHSTWIN
dc autosense
ModelDC PRIORITYMount
DBC0115F1V71-1HIGH BAND - LED INDICATORSINGLE
DBC0115F1V71-2HIGH BAND - LED INDICATORTWIN
DBC0115F1V72-1LOW BAND - LED INDICATORSINGLE
DBC0115F1V72-2LOW BAND - LED INDICATORTWIN
DBC0115F1V91-1HIGH BAND - NO LEDSINGLE
DBC0115F1V91-2HIGH BAND - NO LEDTWIN
DBC0115F1V92-1LOW BAND - NO LEDSINGLE
DBC0115F1V92-2LOW BAND - NO LEDTWIN
The DC/AISG path is automatically selected. In bottom of the tower applications (combiner mode), each RF channel port is sequentially checked for the presence of DC voltage. If more than one port has voltage, the port that has the highest (programmed) priority is passed to the common port. If a short circuit is detected on the common port DC/AISG is disabled. In top-of-tower applications (splitter mode), DC/AISG is passed to all ports that do not present a short circuit. If a short circuit is detected, the shorted RF port will be disabled for DC/AISG while other RF ports remain connected. To reduce current consumption at low supply voltage, LEDs are sequentially enabled.
optional mounting
ModelDC CONFIGURATIONMount
DBC0115F1VXX-6LPER DIPLXER MODEL SELECTED
REFER TO TABLE ABOVE
6 EA. DBC0115F1VXX-1 DIPLEXER ASSEMBLY
CABLE LADDER MOUNTING
DBC0115F1VXX-6RPER DIPLXER MODEL SELECTED
REFER TO TABLE ABOVE
6 EA. DBC0115F1VXX-1 DIPLEXER ASSEMBLY
19" RACK MOUNTING (23" OPTIONAL) - 3U
DBC0115F1VXX-6KNOT APPLICABLE19"/3U RACK KIT – FOR INSTALLATION OF UP TO 6 EA. DBC0115F1VXX-1 DIPLEXERS
electrical block diagram
ELECTRICAL BLOCK DIAGRAM ELECTRICAL BLOCK DIAGRAM
mechanical block diagram
MECHANICAL BLOCK DIAGRAM MECHANICAL BLOCK DIAGRAM
MECHANICAL BLOCK DIAGRAM MECHANICAL BLOCK DIAGRAM