TBC0030F2V1-2

TRIPLEXER 700-850/1900/AWS

Designed to combine 700-850, 1900 and AWS technologies, the Kaelus TBC0030 saves significant capital and operational expenses by limiting feeder runs, and components needed on the tower. Available in an outdoor package the TBC0030 has the following features and benefits.

FEATURES

  • Combines 700-850, 1900 and AWS bands
  • DC/AISG bypass options field settable
  • Very low insertion loss
  • Designed for low passive intermodulation

technical specifications
Band Name 700-850 1900 AWS
Passband 698 - 894MHz 1850 - 1990MHz 1695 - 1780MHz / 2110 - 2200MHz
Insertion loss 0.25dB typical 0.30dB typical 0.30dB typical
Return loss 20dB minimum, 24dB typical 22dB minimum, 24dB typical 22dB minimum, 24dB typical
Group delay variation 0.35ns typical @ 700 band
2ns typical @ 850 band
7ns typical for a WCDMA/UMTS
single carrier bandwidth
2ns typical for a WCDMA/UMTS
single carrier bandwidth
Maximum input power 500W (average) / 5kW (PEP) 500W (average) / 5kW (PEP) 150W (average) / 1.5kW (PEP)
Rejection in 700-850 N/A 70dB minimum, 80dB typical 70dB minimum, 80dB typical
Rejection in 1900 70dB minimum, 80dB typical N/A 50dB minimum, 55dB typical
Rejection in AWS 70dB minimum, 80dB typical 50dB minimum, 58dB typical N/A
electrical
Impedance 50Ohms
Intermodulation products -161dBc typical / -153dBc maximum all ports with 2 x 20W carriers
dc / aisg
A field selectable DC/AISG path is achieved via mechanical links on an IEC60130-9, 8-pin female connector (see mechanical diagram). Kaelus recommend that, due to AISG link budget reasons, a maximum of 2 DC/AISG paths are activated simultaneously without active repeating of the AISG signal.
Passband 0 - 3MHz
Insertion loss, single DC/AISG pass 1dB maximum
Return loss, single DC/AISG pass 12dB minimum
Insertion loss, two DC/AISG pass 4.5dB typical
Return loss, two DC/AISG pass 9dB typical
Input voltage range ± 31V
DC current rating 2A continuous, 4A peak
environmental
For further details of environmental compliance, please contact Kaelus.
Temperature range -40ºC to +65ºC | -40ºF to +149ºF
Ingress protection IP67
Altitude 2,000m | 6,560ft
Lightning protection IEC61000-4-5, RF: ±5kA maximum (8/20us)
MTBF >1,000,000 hours
Compliance ETSI EN 300 019 class 4.1, RoHS
mechanical
Dimensions H x D x W (single unit) 250 x 200 x 71mm | 9.8 x 7.9 x 2.8in (excluding bracket)
Dimensions H x D x W (twin unit) 250 x 200 x 145mm | 9.8 x 7.9 x 5.7in (excluding bracket)
Weight 6kg | 13.23lbs (single unit)
12kg | 26.46lbs (twin unit)
Finish Powder coated, light grey (RAL7035)
Connectors DIN 7-16 (F) x 4 long neck (single unit)
Mounting Pole/wall bracket supplied with two metal clamps for 45-178 mm diameter poles for single and twin unit
ordering information
Part Number Configuration Optional Features Connectors DC/AISG Configuration
TBC0030F2V1-1 SINGLE 1 in /3 out DC SWITCH 7/16 (F) FIELD CONFIGURABLE
TBC0030F2V1-2 TWIN 2 in / 6 out DC SWITCH 7/16 (F) FIELD CONFIGURABLE
TBC0030F2V1-6R RACK 6 in / 18 out DC SWITCH 7/16 (F) FIELD CONFIGURABLE
electrical block diagram
ELECTRICAL BLOCK DIAGRAM
mechanical block diagram
MECHANICAL BLOCK DIAGRAM

GET A QUOTE