DBC0097F2V51-1

TWIN SAME BAND COMBINER, 1900

Designed to combine two 1900MHz BTS with minimum 5MHz spacing, the Kaelus DBC0097 provides a compact twin combining solution with low insertion. The DBC0097 solution minimizes feeders, TMA's and antennas thereby saving both capital and operational expenditure when combining two base stations.
 
Scroll down to see complete list of all DBC0097 models and proper channel placement info. 

FEATURES

  • Allows CDMA and LTE base stations to share feeders, TMAs and antennae
  • Low downlink and uplink insertion losses
  • DC/AISG bypass field settable
  • Suitable for indoor and outdoor use
  • Down to 5MHz guard band

technical specifications
Band Name B-1 DOWNLINK (TX)
at BTS1-1, BTS1-2
B-1 UPLINK (RX)
at BTS1-1, BTS1-2
B-2 DOWNLINK (TX)
at BTS2-1, BTS2-2
B-2 UPLINK (RX)
at BTS2-1, BTS2-2
Bandwidth 20MHz (including 500kHz) 20MHz (including 500kHz) 15MHz (including 500kHz) 15MHz (including 500kHz)
Insertion Loss (excluding 500kHz guardband) 0.5dB typical, 1.0dB maximum 0.5dB typical, 1.0dB maximum 0.5dB typical, 1.0dB maximum 0.5dB typical, 1.0dB maximum
isolation
COM port must be terminated in 50ohms
B-1 TX frequency range 35dB typical, 30dB minimum
B-2 TX frequency range 35dB typical, 30dB minimum
B-1 RX frequency range 35dB typical, 30dB minimum
B-2 RX frequency range 35dB typical, 30dB minimum
dc / aisg
A field selectable DC/AISG path is achieved via mechanical links on a IEC60130-9, 8-pin female connector (see mechanical diagram).
Passband 0 – 3MHz
Insertion loss, single DC/AISG pass 1dB maximum
Return loss, single DC/AISG pass 12dB minimum
Insertion loss, two DC/AISG pass 4.5dB typical
Return loss, two DC/AISG pass 9dB typical
Input voltage range ± 31V
DC current rating 2A continuous, 4A peak
electrical
Impedance 50Ohms
Return loss 20dB minimum
Intermodulation products -161dBc typical / -155dBc maximum on all ports with 2 x 20W carriers in RX band
Maximum input power 150W (average) / 1.5kW (PEP)
Guardband (frequency separation between BTS1 and BTS2) 5MHz minimum
environmental
For further details of environmental compliance, please contact Kaelus.
Temperature range -20ºC to +55ºC | +4ºF to +131ºF
Ingress protection IP67
Lightning protection ±5kA maximum (8/20us), IEC61312-1
MTBF >1,000,000 hours
Compliance ETSI EN 300 019 class 4.1, RoHS
mechanical
Dimensions H x D x W 240 x 55 x 450mm | 9.45 x 2.17 x 17.72in
Weight 9kg | 19.84lbs estimate
Finish Painted, light grey (RAL7035)
Connectors DIN 7-16 (F) x 6 long neck
Mounting Pole/wall bracket supplied with two metal clamps for 45-178 mm diameter poles
ordering information
Part Number B-1 Band B-2 Band Description
Note*: For DBC0097F1V51-1, BTS1 band actually includes A3+15MHz lower band; For DBC0097F11V51-1, BTS2 band actually includes G+H+5MHz higher band.
DBC0097F1V51-1 A3 A5,D&B3 Twin Same Band Combiner 1900
DBC0097F2V51-1 A3 & A4 D,B3&B4 Twin Same Band Combiner 1900
DBC0097F3V51-1 A B Twin Same Band Combiner 1900
DBC0097F4V51-1 A&D B4,B5&E Twin Same Band Combiner 1900
DBC0097F5V51-1 A4,A5,D&B3 B5,E & F Twin Same Band Combiner 1900
DBC0097F6V51-1 A5,D,B3&B4 E, F & C3 Twin Same Band Combiner 1900
DBC0097F7V51-1 D&B F, C3&C4 Twin Same Band Combiner 1900
DBC0097F8V51-1 B&E C Twin Same Band Combiner 1900
DBC0097F9V51-1 B4,B5,E&F C4, C5&G Twin Same Band Combiner 1900
DBC0097F10V51-1 B5,E, F&C3 C5, G&H Twin Same Band Combiner 1900
DBC0097F11V51-1* E, F, C3&C4 G&H Twin Same Band Combiner 1900
electrical block diagram
ELECTRICAL BLOCK DIAGRAM
mechanical block diagram
MECHANICAL BLOCK DIAGRAM

GET A QUOTE