TMA2116F00V1-1

TWIN TMA AWS/WCS, LOWPASS

Designed to be deployed in co-located AWS & WCS systems with wideband antennas, the Kaelus TMA provides internal diplexing and gain in both bands while allowing 700/850 services to pass through to a separate antenna, thereby saving hardware costs

FEATURES

  • Improved base station sensitivity through gain in AWS and WCS bands
  • High linearity and low noise performance; Bypass provided for 700/850MHz services
  • Hardware and software configuration using AISG “Personality” upload
  • Fail safe bypass mode with lightning protection

technical specifications
Band Name AWS WCS
downlink
Passband 2110 - 2180MHz 2350 - 2360MHz
Insertion loss 0.4dB typical 0.5dB typical
Return loss 18dB minimum
Maximum input power 160W (average) / 2kW (PEP) 120W (average) / 1.2kW (PEP)
uplink
Passband 1710 - 1780MHz 2305 - 2315MHz
Gain 13dB 12dB
Variable gain 3dB to 13dB in 1dB steps (controlled by AISG commands) 2dB to 12dB in 1dB steps (controlled by AISG commands)
Gain variation ±1dB maximum
Return loss 18dB minimum operating, 12dB in bypass
Bypass return loss 18dB minimum typical, 14dB minimum guarantied
Bypass loss 2.5dB typical 3.3dB typical
Noise figure 1.3dB typical 1.7dB typical
Output IP3 +30dBm typical
Maximum input power with no damage +12dBm maximum
Rejection 27.5dB minimum@2324.54 - 2341.285MHz
low band path
Passband 698 - 896MHz
Return loss 18dB minimum
Insertion loss 0.35dB typical
Maximum input power with no damage 200W (average) / 2kW (PEP)
electrical
Impedance 50Ohms
Intermodulation products -153dBc maximum in RX band with 2 x 20 carriers
power supply and alarm (current window alarm mode, default)
Current window alarm mode (CWA) is the default TMA operating mode and can be configured to specific customer requirements. The generic personality (F00V1) is configured so that both channels are independently powered and monitored via the respective BTS port. The BTS port sinks additional current to indicate an alarm state in its uplink path. Normal operating and alarm current values are configured independently via a field-loadable personality file, Please contact Kaelus for more information.
DC supply voltage 8.5 to 30V DC, case is DC ground
DC supply Each BTS powered individually (programmable)
DC supply current, normal mode 200 ± 20mA per port (programmable)
DC supply current, alarm mode 300 ± 30mA per port(programmable)
aisg mode of operation (auto selected on valid aisg 2.0 frames)
AISG signals can be applied to either BTS1 or BTS2 ports. The TMA2116FxxVx-1 unit switches to AISG mode when valid frames are detected on one of the BTS ports. Both LNAs take DC power from the port with AISG frames or, if DC is present on both ports, both channels supply equal power to the TMA2116FxxVx-1.
DC supply voltage +8.5V to +30V DC
AISG version 2.0 (1.1 optional)
Supply current, AISG mode 400mA @ 8.5V, 120mA @ 30V typical
AISG connector, current rating IEC60130-9, 8-pin female ,< 4A peak, 2A continuous, pin 6
Field firmware upgradable Yes
environmental
For further details of environmental compliance, please contact Kaelus.
Temperature range -40ºC to +65ºC | -40°F to +149°F
Ingress protection IP67
Lightning protection IEC61312-1, RF: ±5kA maximum (8/20us), AISG: ±2kA maximum (8/20us)
MTBF >1,000,000 hours
Compliance FCC part 15, ETSI EN 300 019 class 4.1, RoHS
mechanical
Dimensions H x D x W 300 x 215x 123mm | 11.8 x 8.46 x 4.8in
Weight 11kg | 24lbs
Finish Painted, light grey (RAL7035)
Connectors 4.3-10 (F) x 8 long shank, AISG (F) x 1
Mounting Pole/wall bracket supplied with two metal clamps 45-178mm diameter poles
ordering information
Part Number Configuration Optional Features Connectors
TMA2116F00V1-1 TWIN 2 in / 6 out STANDARD 4.3-10 (F)
electrical block diagram
ELECTRICAL BLOCK DIAGRAM
mechanical block diagram
MECHANICAL BLOCK DIAGRAM

GET A QUOTE