TMA2093F02V1-1D

TMA2093F02V1-1D

TWIN TMA PCS/AWS WITH LOW BAND BYPASS

Designed to be deployed in co-located AWS, PCS1900 and low band (698-960) systems with wideband antennas, the Kaelus TMA2093 provides internal duplexing in all three bands with uplink gain in the high bands. A passive Tx/Rx path is provided to a low-band antenna port, thereby saving capital expenditure and tower leasing fees.

FEATURES

  • Improved base station sensitivity through gain in the AWS and PCS uplink bands
  • Excellent noise figure performance
  • Internal duplexing of 698-960MHz signals to be passed to additional ANT ports
  • AISG2.0 compatible, hardware & software configuration using AISG “personality” upload
  • Internal duplexing of AWS and PCS bands
  • DC/AISG bypass onto low band main (optional)

technical specifications
Band NamePCSAWS
downlink
Passband1930 - 1990MHz2110 - 2180MHz
Insertion loss0.8dB typical0.4dB typical
Return loss18dB minimum
Maximum input power160W (average) / 2kW (PEP)160W (average) / 2kW (PEP)
Intermodulation products-153dBc maximum, (3rd order) in RX band with 2 x 20W carriers-153dBc maximum, (7th order) in RX band with 2 x 20W carriers
uplink
Passband1850 - 1910MHz1710 - 1780MHz
Gain12dB
Gain variation±1dB maximum
Return loss18dB minimum operating, 14dB in bypass mode
Bypass loss2.9dB typical2.6dB typical
Noise figure1.4dB typical
Output IP329dBm typical
Maximum input power with no damage12dBm
low band bypass path
Passband698 - 960MHz
Return loss18dB minimum
Insertion loss0.1dB typical
Maximum input power with no damage120W (average) / 2kW (PEP)
Intermodulation @ antenna ports-153dBc, (3rd order) with 2 x 20W carriers
electrical
Impedance50Ohms
power supply and alarm (current window alarm mode, default)
Current window alarm mode (CWA) is the default TMA operating mode and can be configured to specific customer requirements. The generic personality (F02V1) is configured so that both channels are independently powered and monitored via the respective BTS port. The BTS port sinks additional current to indicate an alarm state in its uplink path. Normal operating and alarm current values are configured independently and can be altered via a field-loadable personality file, contact Kaelus for more information.
DC supply voltage7.5 to 30V DC, case is DC ground
DC supply voltage via BTS-RF cableDC power can be applied to either port
DC power to be drawn from one BTS port only
DC applied to both BTS ports power will only be drawn from BTS1
DC supply current, normal mode150 ± 15mA per port (for F02V1)
DC supply current, alarm mode programmable range150 - 250mA, 220 ± 20mA per port (for F02V1)
aisg mode of operation (auto selected on valid aisg 2.0 frames)
AISG signals can be applied to either BTS1 or BTS2 port. The TMA unit switches to AISG mode when valid frames are detected on one of the BTS ports. Both LNAs take DC power from the port with AISG frames or, if DC is present on both ports, both channels supply equal power to the TMA.
DC supply voltage7.5V to 30V DC
AISG version2.0 (1.1 optional)
Supply current, AISG mode300mA @ 7.5V, 85mA @ 30V typical
AISG connector, current ratingIEC60130-9, 8-pin female ,< 4A peak, 2A continuous, pin 6
Field firmware upgradableYes
environmental
For further details of environmental compliance, please contact Kaelus.
Temperature range-40ºC to +65ºC | -40°F to +149°F
Ingress protectionIP67
Lightning protectionIEC61312-1, RF: ±5kA maximum (8/20us), AISG: ±2kA maximum (8/20us)
MTBF>1,000,000 hours
ComplianceFCC part 15, ETSI EN 300 019 class 4.1, RoHS
mechanical
Dimensions H x D x W300 x 250 x 95mm | 11.8 x 9.8 x 3.7in (excluding brackets and connectors)
Weight10.5kg | 23.1lbs
FinishPainted, light grey (RAL7035)
ConnectorsDIN 7-16 (F) x 6 long neck, AISG (F) x 1
MountingPole/wall bracket supplied with two metal clamps 45-178mm diameter poles
ordering information
Part NumberDescription
TMA2093F02V1-1DTwin TMA 1900/AWS, 698-960 bypass, 4 ANT, configured with AT&T personality
electrical block diagram
ELECTRICAL BLOCK DIAGRAM
mechanical block diagram
MECHANICAL BLOCK DIAGRAM

GET A QUOTE