DDF0015F4V2-1

TWIN DUAL DUPLEXED FILTER E900


The DDF0015 is deployed when co-locating 900 and 850MHz systems. Attenuating the 850MHz downlink band this filter prevents the 900MHz BTS receive being overloaded from 850MHz systems.

FEATURES

  • Filters unwanted carrier frequencies introduced when antennas from both 850 and 900MHz services are co-located
  • Twin dual duplex structure.15MHz bandwidth
  • Excellent rejection in 850MHz band, low loss, high selectivity
  • Factory tuned anywhere in extended 900MHz band if required
  • DC Pass available

TECHNICAL SPECIFICATIONS

BAND NAME DOWNLINK (TX) PATH UPLINK (RX) PATH
RF PERFORMANCE
Passband 945 – 960MHz 900 – 915MHz
Insertion loss 0.4dB typical
Return loss 18dB minimum
Rejection 52dB typical @ 860 – 890MHz
ELECTRICAL
Impedance 50ohms
Intermodulation products -160dBc max (5th Order, 2x 20 W carriers)
Maximum input power 120W (average) single carrier
4 carriers, 30W (average per carrier) 800W (PIP)
ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus.
Temperature range -5ºC to +65ºC | 23ºF to +149ºF
Ingress protection IP67 (outdoors)
Lightning protection IEC61312-1
8/20us, +/-5kA max
DC grounded, all ports
MTBF >1,000,000 hours
MECHANICAL
Dimensions H x D x W 239 x 217 x 89mm | 9.4 x 8.54 x 3.5in
Weight 8kg | 17.63lbs
Finish Painted light grey
Connectors DIN 7-16 (F) x 4
Mounting Pole/wall bracket supplied with two metal clamps for 45-178 mm diameter poles

ORDERING INFORMATION

PART NUMBER DESCRIPTION
Other tunings available contact Kaelus for details
DDF0015F4V2-1 TWIN DUAL DUPLEXED FILTER 900-915/945-960 REJ 52 @890, NO DC

ELECTRICAL BLOCK DIAGRAM

MECHANICAL BLOCK DIAGRAM

 

 

 

Related Products

Contact Us
RMA
Support
Career
Resources
Language
Scroll to Top

Access this document

Please enter your details to download the file.
Thank you. You can now access the document below.