MI-147

TMA TWIN 2100/2600


Designed to be deployed in collocated 2100 and 2600 systems, the Kaelus MI-147 enhances cell uplink coverage in 2100 and 2600 through improved system noise figure, thereby saving operational and capital expenditure.

FEATURES

  • Improved base station sensitivity through gain in the 2100 and 2600 uplink
  • Internal diplexing on the antenna port of 2100 and 2600 bands: 2 Antenna ports
  • Excellent noise figure performance
  • Full AISG operation and RET antenna support, AISG2.0 compatible
  • Small and light for minimum visual impact

TECHNICAL SPECIFICATIONS

BAND NAME 2100 2600
DOWNLINK
Passband 2110 – 2170MHz 2620 – 2690MHz
Insertion loss 0.30dB typical 0.35dB typical
Return loss 18dB minimum
Maximum input power 200W (average) 200W (average)
Intermodulation products -168dBc in RX band at ANT -160dBc in RX band at ANT
UPLINK
Passband 1920 – 1980MHz 2500 – 2570MHz
Gain 12dB nominal
Return loss 16dB minimum
Bypass return loss 12dB minimum
Bypass loss 1.9dB typical 2.0dB typical
Noise figure 1.4dB typical 1.5dB typical
Output IP3 25dBm typical
ELECTRICAL
Impedance 50Ohms
AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0 FRAMES)
AISG signals can be applied to the BTS ports. The TMA unit switches to AISG mode when valid frames are detected on either port. Each LNA is controlled uniquely by its sub-unit number.
DC supply voltage 24 V DC nominal (+9.0V to +31V DC)
AISG version 2.0
Power consumption, AISG mode < 4W
AISG connector, current rating IEC60130-9, 8-pin female, 1.6A
ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus.
Temperature range -40ºC to +65ºC | -40°F to +149°F
Ingress protection IP67
Lightning protection IEC61312-1, RF: ±5kA (8/20us), AISG: ±2.5kA (8/20us)
MTBF >1,000,000 hours
Compliance EMC: EN 301 489-23
Safety: EN 60950
Operation: ETSI EN 300 019-1-4 class 4.1E
Storage: ETS 300 019-1-1 class 1.2
MECHANICAL
Dimensions H x D x W 176 x 110 x 154 mm | 6.9 x 4.3 x 6.0in (excluding brackets and connectors)
Weight 4.3kg | 9.48lbs
Finish Powder coated, NCS 1502-R
Connectors See ordering information
Mounting Pole/wall bracket using two metal clamps, suits 40-140mm diameter poles
SHIPPING INFORMATION
Gross weight (including packaging) 4.9kg │ 10.80lb
Carton Qty / Pallet 39

ORDERING INFORMATION

PART NUMBER CONFIGURATION OPTIONAL FEATURES CONNECTORS AISG MODE
MI-14701 TWIN, 2 in / 2 out BASE MODEL 7/16 (F)
1xAISG
COMMON MODE
ONETWO (*)
MI-14702 TWIN, 2 in / 2 out BASE MODEL 7/16 (F)
1xAISG
COMMON MODE
TWOTWO (**)
MI-14706 TWIN, 2 in / 2 out BASE MODEL 7/16 (F)
2xAISG
INDEPENDENT
MI-14731 TWIN, 2 in / 2 out BASE MODEL 4.3-10 (F)
1xAISG
COMMON MODE
ONETWO (*)
MI-14732 TWIN, 2 in / 2 out BASE MODEL 4.3-10 (F)
1xAISG
COMMON MODE
TWOTWO (**)
MI-14736 TWIN, 2 in / 2 out BASE MODEL 4.3-10 (F)
2xAISG
INDEPENDENT
(*) ONETWO: the TMA is identified as 1 logic unit with 2 subunits
(**) TWOTWO: the TMA is identified as 2 logic units with 2 subunits each

ELECTRICAL BLOCK DIAGRAM