TMA TWIN 1800/2600
Designed to be deployed in collocated 1800 and 2600 systems, the Kaelus MI-168 enhances cell uplink coverage in 1800 and 2600 through improved system noise figure, thereby saving operational and capital expenditure.
FEATURES
- Improved base station sensitivity through gain in the 1800 and 2600 uplink
- 4 Antenna ports
- Excellent noise figure performance
- Full AISG operation and RET antenna support, AISG2.0 compatible
- Small and light for minimum visual impact
TECHNICAL SPECIFICATIONS |
|||||||||||||||
| BAND NAME | 1800 | 2600 | |||||||||||||
| DOWNLINK | |||||||||||||||
| Passband | 1805 – 1880MHz | 2620 – 2690MHz | |||||||||||||
| Insertion loss | 0.5dB typical 0.7dB max |
0.4dB typical | |||||||||||||
| Return loss | 18dB minimum | ||||||||||||||
| Maximum input power | 200W (average) | 200W (average) | |||||||||||||
| Intermodulation products | -160dBc in RX band at ANT | ||||||||||||||
| UPLINK | |||||||||||||||
| Passband | 1710 – 1785MHz | 2500 – 2570MHz | |||||||||||||
| Gain | 12dB nominal | ||||||||||||||
| Return loss | 16dB minimum | ||||||||||||||
| Bypass return loss | 12dB minimum | ||||||||||||||
| Bypass loss | 2.7dB typical | 2.6dB typical | |||||||||||||
| Noise figure | 1.5dB typical | ||||||||||||||
| Output IP3 | 25dBm typical | ||||||||||||||
| Maximum input power with no damage | 12dB typical | ||||||||||||||
| ELECTRICAL | |||||||||||||||
| Impedance | 50Ohms | ||||||||||||||
| AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0 FRAMES) | |||||||||||||||
| AISG signals can be applied to the BTS ports. The TMA unit switches to AISG mode when valid frames are detected on either port. | |||||||||||||||
| DC supply voltage | +9.0V to +30V DC | ||||||||||||||
| AISG version | 1.1 or 2.0 | ||||||||||||||
| Power consumption, AISG mode | < 4W | ||||||||||||||
| AISG connector, current rating | IEC60130-9, 8-pin female, 1.6A | ||||||||||||||
| ENVIRONMENTAL | |||||||||||||||
| For further details of environmental compliance, please contact Kaelus. | |||||||||||||||
| Temperature range | -40ºC to +65ºC | -40°F to +149°F | ||||||||||||||
| Ingress protection | IP67 | ||||||||||||||
| MTBF | >1,000,000 hours | ||||||||||||||
| Compliance | EMC: EN 301 489-8 Safety: IEC/EN 62368-1 Operation: ETSI EN 300 019-1-4 class 4.1E Storage: ETS 300 019-1-1 class 1.2 |
||||||||||||||
| MECHANICAL | |||||||||||||||
| Dimensions H x D x W | 224 x 109 x 209 mm | 8.8 x 4.3 x 8.2in (excluding brackets and connectors) | ||||||||||||||
| Weight | 6.9kg | 15.21lbs | ||||||||||||||
| Finish | Powder coated, NCS 1502-R | ||||||||||||||
| Connectors | See ordering information | ||||||||||||||
| Mounting | Pole/wall bracket using two metal clamps, suits 40-140mm diameter poles | ||||||||||||||
SHIPPING INFORMATION |
|||||||||||||||
| Carton size | 355 x 265 x 178 mm │ 13.98 x 10.43 x 7.01 in | ||||||||||||||
| Gross weight (including packaging) | 7.7kg │ 16.98lb | ||||||||||||||
| Carton Qty / Pallet | 48 | ||||||||||||||
ORDERING INFORMATION |
|||||||||||||||
| PART NUMBER | CONFIGURATION | OPTIONAL FEATURES | CONNECTORS | AISG MODE | |||||||||||
| MI-16801 | TWIN, 2 in / 4 out | BASE MODEL | 7/16 (F) 1xAISG |
COMMON MODE ONETWO (*) |
|||||||||||
| MI-16802 | TWIN, 2 in / 4 out | BASE MODEL | 7/16 (F) 1xAISG |
COMMON MODE TWOTWO (**) |
|||||||||||
| MI-16806 | TWIN, 2 in / 4 out | BASE MODEL | 7/16 (F) 2xAISG |
INDEPENDENT | |||||||||||
| MI-16831 | TWIN, 2 in / 4 out | BASE MODEL | 4.3-10 (F) 1xAISG |
COMMON MODE ONETWO (*) |
|||||||||||
| MI-16832 | TWIN, 2 in / 4 out | BASE MODEL | 4.3-10 (F) 1xAISG |
COMMON MODE TWOTWO (**) |
|||||||||||
| MI-16836 | TWIN, 2 in / 4 out | BASE MODEL | 4.3-10 (F) 2xAISG |
INDEPENDENT | |||||||||||
| (*) ONETWO: the TMA is identified as 1 logic unit with 2 subunits | |||||||||||||||
| (**) TWOTWO: the TMA is identified as 2 logic units with 2 subunits each | |||||||||||||||
ELECTRICAL BLOCK DIAGRAM |