TMA TWIN 1800/2100/2600 WITH L-BAND BYPASS
Designed to be deployed in collocated 1800, 2100, 2600 and L band systems, the Kaelus MI-185 enhances cell uplink coverage in 1800, 2100 and 2600 through improved system noise figure, thereby saving operational and capital expenditure.
FEATURES
- Improved base station sensitivity through gain in the 1800, 2100 and 2600 uplink
- L-Band bypass
- Internal diplexing: 2 Antenna ports
- Excellent noise figure performance
- Full AISG operation and RET antenna support, AISG2.0 compatible
- Small and light for minimum visual impact
TECHNICAL SPECIFICATIONS |
|||||||||||||||
| BAND NAME | 1800 | 2100 | 2600 | ||||||||||||
| DOWNLINK | |||||||||||||||
| Passband | 1805 – 1880MHz | 2110 – 2170MHz | 2620 – 2690MHz | ||||||||||||
| Insertion loss | 0.5dB typical | 0.4dB typical | 0.4dB typical | ||||||||||||
| Return loss | 20dB typical, 18dB minimum | ||||||||||||||
| Maximum input power | 200W (average)* | 200W (average)* | 200W (average)* | ||||||||||||
| Intermodulation products | -160dBc in RX band at ANT | ||||||||||||||
| UPLINK | |||||||||||||||
| Passband | 1710 – 1785MHz | 1920 – 1980MHz | 2500 – 2570MHz | ||||||||||||
| Gain | 12dB | ||||||||||||||
| Return loss | 16dB minimum | ||||||||||||||
| Bypass return loss | 12dB minimum | ||||||||||||||
| Bypass loss | 2dB typical | 2.2dB typical | 2dB typical | ||||||||||||
| Noise figure | 1.4dB typical | 1.4dB typical | 1.4dB typical | ||||||||||||
| Output IP3 | 25dBm typical | ||||||||||||||
| L-BAND | |||||||||||||||
| Passband | 1427 – 1517MHz | ||||||||||||||
| Insertion loss | 0.25dB typical | ||||||||||||||
| Maximum input power | 200W average (*) | ||||||||||||||
| (*) Limited to 500W (average) combined power at the ANT and BTS ports |
| ELECTRICAL | |||||||||||||||
| Impedance | 50Ohms | ||||||||||||||
| AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0 FRAMES) | |||||||||||||||
| AISG signals can be applied to the BTS ports. The TMA unit switches to AISG mode when valid frames are detected on either port. | |||||||||||||||
| DC supply voltage | +9.0V to +31V DC | ||||||||||||||
| AISG version | 2.0 | ||||||||||||||
| Power consumption, AISG mode | < 4W | ||||||||||||||
| AISG connector, current rating | IEC60130-9, 8-pin female | ||||||||||||||
| ENVIRONMENTAL | |||||||||||||||
| For further details of environmental compliance, please contact Kaelus. | |||||||||||||||
| Temperature range | -40ºC to +65ºC | -40°F to +149°F | ||||||||||||||
| Ingress protection | IP67 | ||||||||||||||
| Lightning protection | RF: ±5kA (8/20us), AISG: ±2.5kA (8/20us) | ||||||||||||||
| MTBF | >1,000,000 hours | ||||||||||||||
| Compliance | EMC: EN 301 489-23 Safety: IEC/EN 62368-1 Operation: ETSI EN 300 019-1-4 class 4.1E Storage: ETSI 300 019-1-1 class 1.2 |
||||||||||||||
| MECHANICAL | |||||||||||||||
| Dimensions H x D x W | 226 x 111 x 341 mm | 8.9 x 4.3 x 13.4in (excluding brackets and connectors) | ||||||||||||||
| Weight | 10kg | 22.05lbs | ||||||||||||||
| Finish | Powder coated, NCS 1502-R | ||||||||||||||
| Connectors | See ordering information | ||||||||||||||
| Mounting | Pole/wall bracket using two metal clamps, suits 40-140mm diameter poles | ||||||||||||||
ORDERING INFORMATION |
|||||||||||||||
| PART NUMBER | CONFIGURATION | OPTIONAL FEATURES | CONNECTORS | AISG MODE | |||||||||||
| MI-18501 | TWIN, 2 in / 2 out | BASE MODEL | 7/16 (F) 1xAISG |
COMMON MODE TWOTWO (*) |
|||||||||||
| MI-18502 | TWIN, 2 in / 2 out | BASE MODEL | 7/16 (F) 1xAISG |
COMMON MODE TRITWO (**) |
|||||||||||
| MI-18506 | TWIN, 2 in / 2 out | BASE MODEL | 7/16 (F) 2xAISG |
INDEPENDENT | |||||||||||
| MI-18531 | TWIN, 2 in / 2 out | BASE MODEL | 4.3-10 (F) 1xAISG |
COMMON MODE TWOTWO (*) |
|||||||||||
| MI-18532 | TWIN, 2 in / 2 out | BASE MODEL | 4.3-10 (F) 1xAISG |
COMMON MODE TRITWO (**) |
|||||||||||
| MI-18536 | TWIN, 2 in / 2 out | BASE MODEL | 4.3-10 (F) 2xAISG |
INDEPENDENT | |||||||||||
| (*) TWOTWO: the TMA is identified as 2 logic units with 2 subunits each | |||||||||||||||
| (**) TRITWO: the TMA is identified as 3 logic units with 2 subunits each | |||||||||||||||
ELECTRICAL BLOCK DIAGRAM |

MECHANICAL BLOCK DIAGRAM |