TWIN TMA 1800/2100/2600 LOW-BAND BYPASS
Designed to be deployed in co-located Low band, 1800, 2100 and 2600MHz systems with wideband antennas, this Tower Mounted Amplifier provides gain in all of the high bands.
FEATURES
- Improved base station sensitivity through gain in the 1800, 2100 and 2600 uplink bands
- 694-960MHz passed to low band antenna ports
- Internal diplexing of 1800, 2100 and 2600MHz bands
- AISG2.0 compatible
- Compact, low weight
- Excellent noise figure performance
TECHNICAL SPECIFICATIONS |
|||||||||||||||
| BAND NAME | 1800 | 2100 | 2600 | ||||||||||||
| DOWNLINK | |||||||||||||||
| Passband | 1805 – 1880MHz | 2110 – 2170MHz | 2620 – 2690MHz | ||||||||||||
| Insertion loss | 0.5dB typical | 0.4dB typical | 0.4dB typical | ||||||||||||
| Return loss | 18dB minimum | ||||||||||||||
| Maximum input power | 200W average* | 200W average* | 200W average* | ||||||||||||
| Intermodulation products | -160dBc in RX band at ANT | ||||||||||||||
| UPLINK | |||||||||||||||
| Passband | 1710 – 1785MHz | 1920 – 1980MHz | 2500 – 2570MHz | ||||||||||||
| Gain | 12dB | ||||||||||||||
| Return loss | 16dB minimum | ||||||||||||||
| Bypass return loss | 12dB minimum | ||||||||||||||
| Bypass loss | 2.0dB typical | 2.2dB typical | 2.0dB typical | ||||||||||||
| Noise figure | 1.4dB typical | ||||||||||||||
| Output IP3 | +25dBm typical | ||||||||||||||
| LOW BAND BYPASS PATH | |||||||||||||||
| Passband | 694 – 960MHz | ||||||||||||||
| Return loss | 18dB minimum | ||||||||||||||
| Insertion loss | 0.2dB typical | ||||||||||||||
| Maximum input power with no damage | 200W average* | ||||||||||||||
| (*) Versions with 4.3-10 (F) connectors are limited to 500W (average) combined power. |
| ELECTRICAL | |||||||||||||||
| Impedance | 50Ohms | ||||||||||||||
| AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0 FRAMES) | |||||||||||||||
| AISG signals can be applied to the BTS ports. The TMA unit switches to AISG mode when valid frames are detected on either port. Each LNA is controlled uniquely by its sub-unit number. | |||||||||||||||
| DC supply voltage | 24 V DC nominal +9.0V to +31V DC |
||||||||||||||
| AISG version | 2.0 | ||||||||||||||
| Power consumption, AISG mode | < 4W | ||||||||||||||
| AISG connector, current rating | IEC60130-9, 8-pin female | ||||||||||||||
| ENVIRONMENTAL | |||||||||||||||
| For further details of environmental compliance, please contact Kaelus. | |||||||||||||||
| Temperature range | -40ºC to +65ºC | -40°F to +155°F | ||||||||||||||
| Ingress protection | IP67 | ||||||||||||||
| Lightning protection | RF: ±5kA (8/20us), AISG: ±2kA common mode (8/20us) | ||||||||||||||
| MTBF | >1,000,000 hours | ||||||||||||||
| Compliance | EMC: EN 301 489-23 Safety: EN 62368-1 Operation: ETSI EN 300 019-1-4 class 4.1E Storage: ETSI 300 019-1-1 class 1.2 |
||||||||||||||
| MECHANICAL | |||||||||||||||
| Dimensions H x D x W | 231 x 125 x 309mm | 9.09 x4.92 x 12.16in (excluding brackets and connectors) | ||||||||||||||
| Weight | 12kg | 26.45lbs | ||||||||||||||
| Finish | Powder coated, NCS 1502-R | ||||||||||||||
| Mounting | Pole/wall bracket using two metal clamps, suits 40-140mm diameter poles | ||||||||||||||
ORDERING INFORMATION |
|||||||||||||||
| PART NUMBER | CONFIGURATION | OPTIONAL FEATURES | CONNECTORS | AISG MODE | |||||||||||
| TMA2142F01V1-1 | TWIN, 2 in / 4 out | BASE MODEL | 4.3-10 (F) 1 x AISG |
TRITWO | |||||||||||
| TMA2142F01V2-1 | TWIN, 2 in / 4 out | BASE MODEL | 7-16 (F) 1 x AISG |
TRITWO | |||||||||||
| MI-19101 | TWIN, 2 in / 4 out | BASE MODEL | 7/16 (F) 1 x AISG |
TWOTWO | |||||||||||
| MI-19102 | TWIN, 2 in / 4 out | BASE MODEL | 7/16 (F) 1 x AISG |
TRITWO | |||||||||||
| MI-19106 | TWIN, 2 in / 4 out | BASE MODEL | 7/16 (F) 2 x AISG |
INDEPENDENT MODE | |||||||||||
| MI-19131 | TWIN, 2 in / 4 out | BASE MODEL | 4.3-10 (F) 1 x AISG |
TWOTWO | |||||||||||
| MI-19132 | TWIN, 2 in / 4 out | BASE MODEL | 4.3-10 (F) 1 x AISG |
TRITWO | |||||||||||
| MI-19136 | TWIN, 2 in / 4 out | BASE MODEL | 4.3-10 (F) 2 x AISG |
INDEPENDENT MODE | |||||||||||
| Note: in the AISG mode “TWOTWO ” the multi band TMA is seen as 2 logic units with 2 subunits each and it is only required to connect to one of the two BTS ports. Either port can be used. | |||||||||||||||
| Note: in the AISG mode “TRITWO ” the multi band TMA is seen as 3 logic units with 2 subunits each and it is only required to connect to one of the two BTS ports. Either port can be used. | |||||||||||||||
ELECTRICAL BLOCK DIAGRAM |

MECHANICAL BLOCK DIAGRAM |