MI-233

TRIPLEXER 800/900/1800-2100

The Kaelus MI-233 is a bi-directional Triplexer, designed to combine or split 800/900/1800-2100 MHz. The MI-233 provides low insertion loss and high return loss with excellent passive inter-modulation performance in an extremely small and lightweight IP67 capable package

FEATURES

  • Enables antenna & coax sharing for 800/900/1800-2100 MHz bands systems.
  • Compact & lightweight – perfect for Small Cell applications
  • Low insertion loss & high return loss
  • High passive IM performance
  • Single and dual models available
  • 7/16 (F) or 4.3-10 (F) connectors
  • Hard Wired and DC Autosense versions available
  • Provisions for wall or mast mounting

TECHNICAL SPECIFICATIONS

BAND NAME 800 900 1800-2100
Passband 790 – 862 MHz 880 – 960 MHz 1710 – 2170 MHz
Insertion loss 0.2 dB typical, 0.4 dB maximum 0.2 dB typical, 0.4 dB maximum 0.2 dB typical, 0.4 dB maximum
Return loss >18 dB >18 dB >18 dB
Maximum input power 250W
Intermodulation products -159 dBc at 2 x 43dBm TX Carrier
Rejection 50 dB minimum in 880 – 2690 MHz 50 dB minimum in 790 – 862 and 1710 – 2170 MHz 50 dB minimum in 790 – 960 MHz
ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus.
Temperature range -40 ºC to +65 ºC | -40 ºF to +149 ºF
Ingress protection IP67
Lightning protection 5 kA maximum (8/20 us)
MTBF > 1,000,000 Hours
Compliance ETSI EN 300 019-1-4 class 4.1E, RoHS
ELECTRICAL
Impedance 50 Ω
DC / AISG
For hardwired versions, DC/AISG can be fully connected (DC all) or a specific connection can be orderd (DC custom).
For DC autosense versions, the DC/AISG path is automatically selected. In bottom of the tower applications (combiner mode), each RF channel port is sequentially checked for the presence of DC voltage. If more than one port has voltage, the port that has the highest (programmed) priority is passed to the common port. If a short circuit is detected on the common port DC/AISG is disabled. In top-of-tower applications (splitter mode), DC/AISG is passed to all ports that do not present a short circuit. If a short circuit is detected, the shorted RF port will be disabled for DC/AISG while other RF ports remain connected.
Insertion loss 1 dB max
Return loss 12 dB min
Input voltage range 8 – 30 V DC max 0.3 W
DC current rating 3 A continuous, Drop max 2.4 V
Compliance 3GPP TS 37.461
MECHANICAL
Feature Single Mount Dual Mount
Dimensions H x D x W 220 x 160 x 58 mm I 8.66 x 6.30 x 2.28 in 220 x 160 x 124 mm I 8.66 x 6.30 x 4.69 in
Volume 2.0 l 4.2 l
Weight 3.6 kg/3.0 kg I 7.9 lb/6.6 lb 6.0kg/5.4 kg I 13.2 lb/11.9 lb
Finish Painted, NCS 1502-R ( Light Grey )
Mounting Hose clamps or wall mount ( Supporter pole Diameter: 40 – 140 mm )
Feature Single Mount with Auto-Sense Dual Mount with Auto-Sense
Dimensions H x D x W TBD 220 mm x 160 mm x 141 mm I 8.66 x 6.30 x 5.55 in
Volume 2.0 L 5.0 l
Weight 3.6 kg/3.0 kg I 7.9 lb/6.6 lb 6.5 kg/5.9 kg l 14.3 lb/13 lb
Finish Painted, NCS 1502-R ( Light Grey )
Mounting Hose clamps or wall mount ( Supporter pole Diameter: 40 – 140 mm )

ORDERING INFORMATION

PART NUMBER CONFIGURATION OPTIONAL FEATURES CONNECTORS DC/AISG CONFIGURATION
MI-233n Single Mount BASE MODEL 7/16 (F) Refer to DC /AISG table
MI-2331n Dual Mount BASE MODEL 7/16 (F) Refer to DC /AISG table
MI-233n Single Mount BASE MODEL 4.3-10 (F) Refer to DC /AISG table
MI-233n Dual Mount BASE MODEL 4.3-10 (F) Refer to DC /AISG table
DC / ASIG CONFIGURATION
MI-233nA Auto-sense
MI-233n1 DC TO 1800 – 2100
MI-233n2 DC TO 900
MI-233n3 DC to 800
MI-233n4 DC TO 900 and 1800 – 2100
MI-233n5 DC TO ALL
MI-233n6 DC TO 800 and 1800 – 2100
MI-233n7 DC Block
Auto-sense Priority
MI-233 nA.1 FPO to 800, 900 and 1800 – 2100
MI-233 nA.2 XOR 800, 900 and 1800 – 2100
MI-233 nA.3 1800 – 2100 Priority 1, 900 Priority 2 and 800 Priority 3
MI-233 nA.4 800 Priority 1, 900 Priority 2 and 1800 – 2100 Priority 3
MI-233nA.5 900 Priority 1, 1800 – 2100 Priority 2 and 800 Priority 3
MI-233nA.6 900 Priority 1, 800 Priority 2 and 1800 – 2100 Priosrity 3
MI-233nA.7 800 Priority 1, 1800 – 2100 Priority 2 and 900 Priority 3
MI-233nA.8 1800 – 2100 Priority 1, 800 Priority 2 and 900 Priority 3

ELECTRICAL BLOCK DIAGRAM

MECHANICAL BLOCK DIAGRAM

 

Related Products

Contact Us
RMA
Support
Career
Resources
Language
Scroll to Top

Access this document

Please enter your details to download the file.
Thank you. You can now access the document below.