MI-551

TRIPLEXER 700 – 900/L-BAND/1800 – 2100

The Kaelus MI-551 is a bi-directional triplexer, designed to combine or split 700 – 900/L-band/1800 – 2100. The MI-551 provides low insertion loss and high return loss with excellent passive inter-modulation performance in an extremely small and lightweight IP67 capable package

FEATURES

  • Enables antenna & coax sharing for 700 – 900/L-band/1800 – 2100 bands systems.
  • Compact & lightweight – perfect for Small Cell applications
  • Low insertion loss & high return loss
  • High passive IM performance
  • Single and dual models available
  • 7/16 (F) or 4.3-10 (F) connectors
  • Hard Wired and DC Autosense versions available
  • Provisions for wall or mast mounting

TECHNICAL SPECIFICATIONS

BAND NAME 700 – 900 L-BAND 1800 – 2100
Passband 698 – 960 MHz 1427 – 1517 MHz 1710 – 2170 MHz
Insertion loss 0.1 dB typical, 0.2 dB maximum 0.25 dB typical 0.2 dB typical
Return loss >18 dB >18 dB >18 dB
Maximum input power 250W
Intermodulation products -160 dBc at 2 x 43dBm TX Carrier -145 dBc at 2 x 43dBm TX Carrier -160 dBc at 2 x 43dBm TX Carrier
Rejection 50 dB minimum in 1427 – 2170 MHz 50 dB minimum in 698 – 960 and 1710 – 2170 MHz 50 dB minimum in 698 – 1517 MHz
ELECTRICAL
Impedance 50 Ω
DC / AISG
For hardwired versions, DC/AISG can be fully connected (DC all) or a specific connection can be orderd (DC custom).
For DC autosense versions, the DC/AISG path is automatically selected. In bottom of the tower applications (combiner mode), each RF channel port is sequentially checked for the presence of DC voltage. If more than one port has voltage, the port that has the highest (programmed) priority is passed to the common port. If a short circuit is detected on the common port DC/AISG is disabled. In top-of-tower applications (splitter mode), DC/AISG is passed to all ports that do not present a short circuit. If a short circuit is detected, the shorted RF port will be disabled for DC/AISG while other RF ports remain connected.
Insertion loss 1 dB max
Return loss 12 dB min
Input voltage range 8 – 30 V DC max 0.3 W
DC current rating 3 A continuous, Drop max 2.4 V
Compliance 3GPP TS 37.461
ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus.
Temperature range -40 ºC to +65 ºC | -40 ºF to +149 ºF
Ingress protection IP67
Lightning protection 5 kA maximum (8/20 us)
MTBF > 1,000,000 Hours
Compliance ETSI EN 300 019-1-4 class 4.1E, RoHS
MECHANICAL
Feature Single Mount Dual Mount
Dimensions H x D x W 160 mm x 160 mm x 50 mm I 6.3 x 6.54 x 1.97 in 160 mm x 160 mm x 94 mm I 6.3 x 6.54 x 3.7 in
Volume 1.3 l 2.5 l
Weight 2.6 kg I 5.73 lb 5 kg I 11.02 lb
Finish Painted, NCS 1502-R ( Light grey )
Mounting Hose clamps or wall mount ( Supporter pole Diameter: 40 – 140 mm )

ORDERING INFORMATION

PART NUMBER CONFIGURATION OPTIONAL FEATURES CONNECTORS DC/AISG CONFIGURATION
MI-5510n Single Mount BASE MODEL 7/16 (F) Refer to DC /AISG table
MI-5511n Dual Mount BASE MODEL 7/16 (F) Refer to DC /AISG table
MI-5513n Single Mount BASE MODEL 4.3-10 (F) Refer to DC /AISG table
MI-5514n Dual Mount BASE MODEL 4.3-10 (F) Refer to DC /AISG table
DC / ASIG CONFIGURATION
MI-551nA Auto-sense
MI-551n1 DC TO 1800 – 2100
MI-551n2 DC TO L-band
MI-551n3 DC TO 700 – 900
MI-551n4 DC TO L-band and 1800 – 2100
MI-551n5 DC TO ALL
MI-551n6 DC TO 700 – 900 and 1800 – 2100
MI-551n7 DC Block
Auto-sense Priority
MI-551nA.1 FPO to 698 – 960, 1427 – 1517 and 1710 – 2170
MI-551nA.2 XOR to FPO to 698 – 960, 1427 – 1517 and 1710 – 2170
MI-551nA.3 1710 – 2170 Priority 1, 1427 – 1517 Priority 2 and 698 – 960 Priority 3
MI-551nA.4 698 – 960 Priority 1, 1427 – 1517 Priority 2 and 1710 – 2170 Priority 3