DIPLEXER 700-900/L-BAND
The Kaelus MI-550 is a bi-directional Diplexer, designed to combine or split 700-900 and L-band. The MI-550 provides low insertion loss and high return loss with excellent passive inter-modulation performance in an extremely small and lightweight IP67 capable package
FEATURES
- Enables antenna & coax sharing for 700-900 and L-band MHz bands systems
- Compact & lightweight – perfect for Small Cell applications
- Low insertion loss & high return loss
- Low passive IM performance
- Single twin and dual twin models available
- 7/16 (F) or 4.3-10 (F) connectors
- Hard Wired and DC Autosense versions available
- Provisions for wall or mast mounting
TECHNICAL SPECIFICATIONS |
|||||||||||||||
| PORT NAME | 700 – 900 | L-BAND | |||||||||||||
| Passband | 698 – 960 MHz | 1427 – 1517 MHz | |||||||||||||
| Insertion loss | < 0.2 dB typical | < 0.25 dB typical | |||||||||||||
| Return loss | >18 dB | >18 dB | |||||||||||||
| Maximum input power | 250 W / 2000 W | ||||||||||||||
| Intermodulation products | -160 dBc with 2 x 43 TX carriers | ||||||||||||||
| Rejection | 50 dB minimum in 1427 – 1517 MHz | 50 dB minimum in 698 – 960 MHz | |||||||||||||
| ELECTRICAL | |||||||||||||||
| Impedance | 50 Ω | ||||||||||||||
| DC / AISG | |||||||||||||||
| For hardwired versions, DC/AISG can be fully connected (DC all) or a specific connection can be orderd (DC custom). For DC autosense versions, the DC/AISG path is automatically selected. In bottom of the tower applications (combiner mode), each RF channel port is sequentially checked for the presence of DC voltage. If more than one port has voltage, the port that has the highest (programmed) priority is passed to the common port. If a short circuit is detected on the common port DC/AISG is disabled. In top-of-tower applications (splitter mode), DC/AISG is passed to all ports that do not present a short circuit. If a short circuit is detected, the shorted RF port will be disabled for DC/AISG while other RF ports remain connected. |
|||||||||||||||
| Insertion loss | 1 dB max | ||||||||||||||
| Return loss | 12 dB min | ||||||||||||||
| Input voltage range | 8 – 30 V DC max 0.3 W | ||||||||||||||
| DC current rating | 2 A continuous, Drop max 2.4 V | ||||||||||||||
| Compliance | 3GPP TS 37.461 | ||||||||||||||
| ENVIRONMENTAL | |||||||||||||||
| For further details of environmental compliance, please contact Kaelus. | |||||||||||||||
| Temperature range | -40 ºC to +65 ºC | -40 ºF to +149 ºF | ||||||||||||||
| Ingress protection | IP67 | ||||||||||||||
| Lightning protection | 10 kA maximum (8/20 us) | ||||||||||||||
| MTBF | > 1,000,000 Hours | ||||||||||||||
| Compliance | ETSI EN 300 019-1-4 class 4.1E, RoHS | ||||||||||||||
| MECHANICAL | |||||||||||||||
| Feature | Single Mount | Dual Mount | |||||||||||||
| Dimensions H x D x W | 99 x 143 x 52 mm I 3.9 x 5.63 x 2.07 in | TBD | |||||||||||||
| Volume | 0.7 l | ||||||||||||||
| Weight | 1.4 kg I 3.09 lb | ||||||||||||||
| Finish | Painted, NCS 1502-R | ||||||||||||||
| Mounting | Hose clamps or wall mount ( Supporter Pole Diameter, 40 – 140 mm ) | ||||||||||||||
ORDERING INFORMATION |
|||||||||||||||
| PART NUMBER | CONFIGURATION | OPTIONAL FEATURES | CONNECTORS | DC/AISG CONFIGURATION | |||||||||||
| MI-5500n | Single Mount | BASE MODEL | 7/16 (F) | Refer to DC /AISG table | |||||||||||
| MI-5501n | Dual Mount | BASE MODEL | 7/16 (F) | Refer to DC /AISG table | |||||||||||
| MI-550n | Single Mount | BASE MODEL | 4.3-10 (F) | Refer to DC /AISG table | |||||||||||
| MI-550n | Dual Mount | BASE MODEL | 4.3-10 (F) | Refer to DC /AISG table | |||||||||||
| DC / ASIG CONFIGURATION | |||||||||||||||
| MI-550nA | Auto-sense | ||||||||||||||
| MI-550n1 | DC Block | ||||||||||||||
| MI-550n2 | DC TO ALL | ||||||||||||||
| MI-550n3 | DC TO L-band | ||||||||||||||
| MI-550n4 | DC to 700 – 900 | ||||||||||||||
| Auto-sense Priority | |||||||||||||||
| MI-550nA.1 | FPO to 698 – 960 and 1427 – 1517 | ||||||||||||||
| MI-550nA.2 | XOR to 698 – 960 and 1427 – 1517 | ||||||||||||||
| MI-550nA.3 | 1427 – 1517 Priority 1 and 698 – 960 Priority 2 | ||||||||||||||
| MI-550nA.4 | 698 – 960 Priority 1 and 1427 – 1517 Priority 2 | ||||||||||||||
ELECTRICAL BLOCK DIAGRAM |

MECHANICAL BLOCK DIAGRAM |