TECHNICAL SPECIFICATIONS

BAND NAME 700-800 900 1800 2100-2600
Passband 694 – 862 MHz 880 – 960 MHz 1710 – 1880 MHz 1920 – 2690 MHz
Insertion loss 0.2 dB typical, 0.5 dB maximum 0.2 dB typical, 0.4 dB maximum 0.2 dB typical, 0.6 dB maximum 0.2 dB typical, 0.7 dB maximum
Return loss >18 dB >18 dB >18 dB >18 dB
Intermodulation products -160 dBc at 2 x 43dBm TX Carrier
Rejection 50 dB minimum in 880 – 2690 MHz 50 dB minimum in 790 – 862, 1710 – 2170, 2300 – 2400, 2500 – 2690 MHz 50 dB minimum in 790 – 960 and 1920 – 2690 MHz 50 dB minimum in 790 – 1880 MHz
ELECTRICAL
Impedance 50 Ω
DC / AISG
For hardwired versions, DC/AISG can be fully connected (DC all) or a specific connection can be orderd (DC custom).
For DC autosense versions, the DC/AISG path is automatically selected. In bottom of the tower applications (combiner mode), each RF channel port is sequentially checked for the presence of DC voltage. If more than one port has voltage, the port that has the highest (programmed) priority is passed to the common port. If a short circuit is detected on the common port DC/AISG is disabled. In top-of-tower applications (splitter mode), DC/AISG is passed to all ports that do not present a short circuit. If a short circuit is detected, the shorted RF port will be disabled for DC/AISG while other RF ports remain connected.
Insertion loss 1 dB max
Return loss 12 dB min
Input voltage range 8 – 30 V DC max 0.3 W
DC current rating 3 A continuous, Drop max 2.4 V
Compliance 3GPP TS 37.461
ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus.
Temperature range -40 ºC to +65 ºC | -40 ºF to +149 ºF
Ingress protection IP67
Lightning protection 5 kA maximum (8/20 us)
MTBF > 1,000,000 Hours
Compliance ETSI EN 300 019-1-4 class 4.1E, RoHS
MECHANICAL
Feature Single Mount Dual Mount
Dimensions H x D x W 267 x 160 x 58 mm I 10.5 x 6.30 x 2.3 in 267 x 160 x 116 mm I 10.5 x 6.30 x 4.6 in
Volume 2.5 l 5.0 l
Weight 4.0 kg I 8.82 lb 6 kg I 13.23 lb
Finish Painted, NCS 1502-R ( Light Grey )
Mounting Hose clamps or wall mount ( Supporter pole Diameter: 40 – 140 mm )
Feature Single Mount Dual Mount
Dimensions H x D x W 267 x 160 x 72 mm I 10.5 x 6.30 x 2.8 in 267 x 160 x 138 mm I 10.5 x 6.30 x 5.4 in
Volume 3.0 l 5.8 l
Weight 4.0 kg I 8.82 lb 6 kg I 13.23 lb
Finish Painted, NCS 1502-R ( Light Grey )
Mounting Hose clamps or wall mount ( Supporter pole Diameter: 40 – 140 mm )

ORDERING INFORMATION

PART NUMBER CONFIGURATION OPTIONAL FEATURES CONNECTORS DC/AISG CONFIGURATION
MI-7570n Single Mount BASE MODEL 7/16 (F) Refer to DC /AISG table
MI-7571n Dual Mount BASE MODEL 7/16 (F) Refer to DC /AISG table
MI-7573n Single Mount BASE MODEL 4.3-10 (F) Refer to DC /AISG table
MI-7574n Dual Mount BASE MODEL 4.3-10 (F) Refer to DC /AISG table
DC / ASIG CONFIGURATION
MI-757nA Auto-sense
MI-757n1 DC BLOCK
MI-757n2 DC TO All
MI-757n3 DC TO 1800
MI-757n4 DC TO 2100-2600
MI-757n5 DC TO 1800 and 2100-2600
MI-757n6 DC TO 700-800, 1800 and 2100-2600
Auto-sense Priority
MI-757nA.1 FPO TO 700-800, 900, 1800 and 2100-2600
MI-757nA.2 XOR TO 700-800, 900, 1800 and 2100-2600
MI-757nA.3 2100-2600 priority 1, 1800 priority 2, 900 priority 3 and 700-800 priority 4
MI-757nA.4 700 – 800 Priority 1, 900 Priority 2 and 1800 Priority 3 and 2100-2600 priority 4
MI-757nA.5 1800 priority 1, 700-800 priority 2, 2100-2600 priority 3 and 900 priority 4
MI-757nA.6 2100-2600 priority 1, 700-800 priority 2, 1800 priority 3 and 900 priority 4
MI-757nA.7 2100-2600 priority 1, 700-800 priority 2, 900 priority 3, and 1800 priority 4

ELECTRICAL BLOCK DIAGRAM

MECHANICAL BLOCK DIAGRAM

Related Products

Contact Us
RMA
Support
Career
Resources
Language
Scroll to Top

Access this document

Please enter your details to download the file.
Thank you. You can now access the document below.