FILTER KIT FOR PIM FINDER SOLUTION (BAND 2,3,5,13)
A challenging category of Product of Intermodulation (PIM) to remedy is external PIM. This refers to PIM generated not in the cell site’s antenna infrastructure but rather in objects in the surrounding environment, for example, loose mounting brackets, roof flashing and structural steel beams.
Identifying the location of external PIM sources has historically been a complicated problem for mobile operators worldwide. To address this measurement challenge, Kaelus offers the PIM Finder Solution.
The PIM finding process requires two 20W tones to be radiated in order to illuminate the PIM sources. The PIM products generated are then captured by a spectrum monitor. Some filtering must be placed at the input of the spectrum monitor to prevent the two 20W tones from generating PIM internally to the spectrum monitor. The filter KIT offers various filters to cater for the testing performed at different frequencies.
FEATURES
- 4 filters in a hard case
- For use with iPA-0707D, iPA-0850D and iPA-1921A
TECHNICAL SPECIFICATIONS |
| SYSTEM | |||||||||||||||
| Passband | iPA receive frequency bands Refer to ordering information |
||||||||||||||
| Insertion loss | 3dB typical | ||||||||||||||
| Rejection | 60dB typical at the iPA transmit frequencies Refer to ordering information |
||||||||||||||
| Maximum input power | 0.5W maximum | ||||||||||||||
ORDERING INFORMATION |
| PROTECTION FILTER | |||||||||||||||
| PART NUMBER | DESCRIPTION | PASSBAND FREQUENCY | STOPBAND FREQUENCY | IPA MODEL | |||||||||||
| R29-4792 | Band 13 – 700 MHz Uplink Filter | 776-787MHz | 728-764MHz | iPA-0707D iXA-0707A |
|||||||||||
| R29-4794 | Band 5 – 850 MHz Low band Uplink Filter | 824-849MHz | 869-894MHz | iPA-0850A | |||||||||||
| OEM124365 | Band 3 – 1750 MHz Uplink Filter | 1710-1785MHz | 1805-1880MHz | iPA-1800A iPA-1921A |
|||||||||||
| OEM124367 | Band 2 – 1900 MHz Uplink Filter | 1850-1910MHz | 1930-1990MHz | iPA-1921A | |||||||||||
PIM FINDER SOLUTION |
| SYSTEM DIAGRAM | |||||||||||||||
| The PIM Finder solution consists of lightweight, easy to use products that are battery powered: 1. A portable PIM Test Analyzer: iPA or iXA* series 2. Range to Fault Module: RTF 3.PIM Test probe: R29-4788 4. Protection Filter from R29-4789 5. Cable and Antenna Analyzer: iVA-0627A 6. Kaelus Unify Software for remote control of iPA and iVA. Running on iOS/Android tablet/phone, or Windows PC (*)The iXA includes 2 integrated RTF, external RTF module not required |
ORDERING INFORMATION |
|||||||||||||||
| PART NUMBER | DESCRIPTION | ||||||||||||||
| iVA-0627A | iVA Cable & Antenna Analyzer System | ||||||||||||||
| iPA series | iPA Battery Portable Passive Intermodulation Analyser | ||||||||||||||
| iXA series | iXA 2-Port Battery Portable Passive Intermodulation Analyser | ||||||||||||||
| R29-4788 | PIM Test probe | ||||||||||||||
| iVA-SW-FI-A | PIM Finder Mode – Software upgrade | ||||||||||||||

| WARNING! RF HAZARD! The radio frequency fields near cellular antennas may exceed safe levels for human exposure. Personnel engaged in troubleshooting external PIM sources should be trained for work in radio frequency environments and use a personal RF monitor if working near active antennas. |
PIM FINDER IN ACTION |