C Band Series 40W

BENCH TOP PIM ANALYZER

The C Band iBA 40W PIM Analyzers are a complete bench top and rack mounting PIM test solution used with a system controller and intuitive user software. The iBA base model (C-Series) measures Reverse/reflected IM only. The D-Series adds a second test port to support a Reverse IM measurement on either port and a forward IM measurement port-to-port.

FEATURES

  • C-Series: Single port unit for reflected PIM testing
  • D-Series: Dual port unit for reflected and foward PIM measurements
  • Fully configurable frequencies, power and IM products
  • Up to 2 x 46dBm power output
  • Frequency sweep and time trace modes
  • Open circuit protection up to 1 hour with power turned on
  • Kaelus API for easy integration with ATE systems
  • Kaelus PIM server software offers the Engineering and Production modes for flexible user interface.

PRODUCT RESOURCES


TECHNICAL SPECIFICATIONS

SYSTEM
Residual PIM (2 x 40W) min< -168 dBc(-122dBm), typical < -171 dBc(-125dBm)
IM order 3rd, 5th, 7th and 9th order
User interface ports 1 x USB Type A
Test ports C-Series: 1 x RF Output (7-16 DIN Female); D-Series: 2 x RF Output (7-16 DIN Female)

TRANSMITTER

Transmit frequencies iBA-3500
TX1: 3520 – 3540MHz
TX2: 3560 – 3600MHz
iBA-3501
TX1: 3660 – 3700MHz
TX2: 3730 – 3800MHz
Frequency increment 100kHz
Frequency accuracy ± 5ppm maximum, aging ± 1ppm maximum after first year
Power per tone (adjustable) +30 to +46dBm | 1W to 40W
Power accuracy (per tone) ± 0.35dB

RECEIVER

Receive band (100kHz steps) iBA-3500
Low Side Reciever 3400-3480MHz
iBA-3501
Low Side Receiver 3500-3600 MHz
High Side Receiver 3850 – 3980MHz
Measurement noise floor < -130 dBm (-135 dBm typical)
Measurement range -48 to -130dBm

ELECTRICAL

Mains power 100 – 240V, 50 – 60Hz AC
Power consumption 1050W (Maximum)

MECHANICAL

Dimensions H x D x W C-Series- 264.2 x 508 x 482.6mm | 10.4 x 20 x 19in
D-Series- 355.3 x 508 x 482.6mm | 14 x 20 x 19in
Weight C-Series- 22.7kg | 50lbs
D-Series- 31.3kg | 69lbs
Cooling Forced air (100mm gap to be maintained at the rear when rack mounted, 1U spacing recommended between units)

ENVIRONMENTAL

Temperature range +10ºC to +40ºC | +50°F to +104°F (operating)
Ingress protection Indoor use (or similar protected outdoor environment)
Operational humidity 5% to 90% non-condensing
Storage temperature range -20°C to +60°C | -4°F to +140°F

PRODUCT

ORDERING INFORMATION
iBA-3500 TX1: 3520 -3540MHz TX2: 3560-3600MHz. RX: 3400 – 3480MHz
iBA-3501 TX1: 3660 – 3700MHz TX2: 3730 – 3800MHz RX1: 3500 – 3600MHz RX2 3850 – 3980MHz
PIL-0006 Low IM Load
R92-0725 Air filter kit – iBA C Series
R92-0726 Air filter kit – iBA D Series
CA123506 Outdoor case for C Band(3500MHz) iBAs
ACE-1000A PIM Instrument self-calibration tool Highly recommended accessory