CABLE AND ANTENNA ANALYZER (560-2750MHZ)
The iVA series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure and locate VSWR/return loss faults in their RF infrastructure. The wireless connectivity allows unprecedented measurement flexibility and opens up new & important possibilities in sweep testing and multi-port testing.The iVA is a rugged battery operated module that can be remotely controlled with any Bluetooth-enabled tablet, smart phone, laptop computer or any of our iPA series Portable Passive Intermodulation analyzers.
FEATURES
- Reinventing site certification sweep testing, dramatically reducing test time on site
- Directly measure insertion loss and isolation when using multiple iVAs. Measure calculated insertion loss with a single iVA and an RF short
- Accurately measure swept VSWR/return loss and Distance-to- Fault in RF path
- Simple and robust Bluetooth connection to a tablet PC or connect with USB or Bluetooth to a laptop computer
- Connect directly to the device under test; eliminates the need for a phase stable cable in most cases
- Uses the Kaelus customer-proven iPA reporting workflow & tagging features to facilitate a faster, simpler and more efficient workflow
- With the Kaelus iPA controlling the iVA, your RL data can be combined with your PIM data into a single report. Reports are combined and completed on-site with no post-processing required
- Simple to operate, highly intuitive software user interface with the unique ability to generate and complete the test report onsite
- Geotag each test point, insert a Google Maps® snapshot directly into the report
- Handy Spectrum Monitor mode for interference checking
- Stimulus mode allows iVA to be used as a signal generator. Can be configured to cycle through a number of frequencies, with a user-defined dwell time at each frequency
- N Type or 4.3-10 Connector options available
PRODUCT RESOURCES |



TECHNICAL SPECIFICATIONS |
| KEY SPECIFICATIONS | |||||||||||||||
| iVA analysis modes | Return loss, VSWR, Cable loss, Distance-to-fault (DTF), Transmission loss, Isolation, Spectrum monitor, | ||||||||||||||
| Frequency range | 560MHz – 2750MHz | ||||||||||||||
| Minimum frequency increment | 1kHz all modes | ||||||||||||||
| Number of measurement points | 1 to 2191 | ||||||||||||||
ELECTRICAL – DC POWER CONSUMPTION |
|||||||||||||||
| Return loss mode | 4.7W | ||||||||||||||
| Transmission mode | 4.7W | ||||||||||||||
| Spectrum monitor mode | 3.7W | ||||||||||||||
| Standby (Idle) | 0.6W | ||||||||||||||
| Battery | Lithium-Ion 3.6V, 2350 mAh, 8.5Wh | ||||||||||||||
| Battery charging method | USB-compatible power source connected to USB port of iVA | ||||||||||||||
| Battery operating time | 8 Hours at typical usage factor | ||||||||||||||
IVA ANALYSIS MODE – RETURN LOSS |
|||||||||||||||
| Sweep speed | 4ms per frequency point | ||||||||||||||
| RF Output power | 0dBm ± 3dB | ||||||||||||||
| Return loss dynamic range | 40dB | ||||||||||||||
| VSWR Dynamic range | 1 – 100:1 | ||||||||||||||
| Cable loss measurement range* | 0 – 20dB | ||||||||||||||
| Return loss measurement accuracy | Applies over the temperature range −10°C to +45°C, with less than 5°C deviation from calibration temperature. | ||||||||||||||
| 0 – 10dB | ± 0.4dB | ||||||||||||||
| 10 – 20dB | ± 0.6dB | ||||||||||||||
| 20 – 30dB | ± 1.5dB | ||||||||||||||
| 30 – 40dB | ± 4.0dB | ||||||||||||||
| Calibrated directivity | 43dB typical | ||||||||||||||
| Interference immunity | +10dBm at 500kHz offset from stimulus frequency | ||||||||||||||
| System impedance | 50ohms | ||||||||||||||
| * Cable loss can be measured either as a 1-port measurement, with the far end of the cable terminated in an open or short circuit, or directly measured for increased accuracy as a 2-port measurement using a second iVA | |||||||||||||||
IVA ANALYSIS MODE – SPECTRUM MONITOR |
|||||||||||||||
| Sweep speed | 2ms per frequency point | ||||||||||||||
| Measurement range | |||||||||||||||
| Low power range | -35 to -115dBm (software default) | ||||||||||||||
| High power range | +20 to -50dBm | ||||||||||||||
| Receiver noise figure (low power range) | 15dB | ||||||||||||||
| Resolution bandwidth | 20kHz | ||||||||||||||
| Displayed average noise level (RBW = 20kHz) | -115dBm low power range, -50dBm high power range | ||||||||||||||
| Measurement accuracy | ±3dB | ||||||||||||||
| Maximum input power without damage | +23dBm | ||||||||||||||
| Input IP3 (low power range) | +18dBm | ||||||||||||||
| Interference immunity | |||||||||||||||
| Low power range | −25dBm at 500kHz offset from stimulus frequency (software default) | ||||||||||||||
| High power range | −5dBm at 500kHz offset from stimulus frequency | ||||||||||||||
| Return loss at iVA test port | 10dB minimum / 15dB typical | ||||||||||||||
STIMULUS MODE |
|||||||||||||||
| Number of carriers | |||||||||||||||
| Minimum | 1 | ||||||||||||||
| Maximum | Unlimited | ||||||||||||||
| Dwell time | |||||||||||||||
| Minimum | 500ms | ||||||||||||||
| Maximum | Unlimited | ||||||||||||||
| RF output power | 0dBm ± 3dB | ||||||||||||||
INSTRUMENT CONTROL |
|||||||||||||||
| User interface | USB or Bluetooth supported user device with iVA application software installed | ||||||||||||||
| Supported Devices | iPA Portable PIM Analyzer Tablet computer (iOS & Android) Smartphone (iOS & Android) PC, Windows 7,8 & 10 running .NET verson 4 or later |
||||||||||||||
| Communications interface to iVA | Bluetooth and USB 2.0 | ||||||||||||||
| Bluetooth antenna | Integrated into housing | ||||||||||||||
| Maximum input power on RF port | +23dBm maximum, DC voltage ±30V | ||||||||||||||
| MECHANICAL | |||||||||||||||
| Dimensions H x D x W | 52 x 69.5 x 216mm | 2.06 x 2.73 x 8.51in | ||||||||||||||
| Weight | 0.68kg | 1.5 lbs | ||||||||||||||
| Connector 1 | RF test port iVA-0627A: Type N male, 50 ohms iVA-0627B: 4.3-10 male, 50 ohms |
||||||||||||||
| Connector 2 | USB 2.0 Mini-B (for charging and connection to iPA or PC) | ||||||||||||||
| Mechanical Shock & Vibration | MIL-PRF-28800F Class 2, ETS 300 019-2-1, -2, -7 | ||||||||||||||
ENVIRONMENTAL |
|||||||||||||||
| Temperature range | -10°C to +55°C | +14°F to +131°F (operational) | ||||||||||||||
| Ingress protection | IP54 | ||||||||||||||
| Altitude | 4600m | 15,000ft maximum | ||||||||||||||
| Compliance | EMC- EN 61326-1:2013, EN 61326-2-1:2013, EN 55022:2010 “Class A” EN 61000-4-2, 4-3, 4-4, 4-5, 4-6, 4-11 Safety- EN 61010-1:2012, EN 61010-030:2012 |
||||||||||||||
| Operational humidity | 5% to 95% RH non-condensing | ||||||||||||||
| Storage temperature range | -20°C to +60°C | -4°F to +140°F | ||||||||||||||
ORDERING INFORMATION |
|||||||||||||||
| PART NUMBER | DESCRIPTION | ||||||||||||||
| iVA-0627A-NC | iVA Cable & Antenna Analyzer System, Type N male connector with Neoprene Soft Case | ||||||||||||||
| iVA-0627A-HC | iVA Cable and Antenna Analyzer System, Type N male connector with Hard Case | ||||||||||||||
| iVA-0627A-BK | iVA Cable & Antenna Analyzer System,Type N male connector with Basic Accessory Kit | ||||||||||||||
| iVA-0627A-SK-02 | iVA Cable & Antenna Analyzer System, Type N male connector with Standard Accessory Kit | ||||||||||||||
| iVA-0627A-PK-02 | iVA Cable & Antenna Analyzer System, Type N male connector with Premium Accessory Kit | ||||||||||||||
| Note: Change A to B for 4.3-10 Connector | Eg. iVA-0627B-NC iVA Cable & Antenna Analyzer System, 4.3-10 male connector with Neoprene Soft Case | ||||||||||||||
MECHANICAL INTERFACE |